Files
sibo-playground/code/inventory/bcode.c
T

47 lines
1.2 KiB
C

/*
* bcode.c - barcode scanner serial channel (see bcode.h).
*/
#include "bcode.h"
GLDEF_C INT bcodeOpen(VOID **pChan)
{
/*
* TTY:D = the top internal slot's serial port, where the barcode module
* sits. mode -1 asks the driver for its default open mode.
*
* If the scanner needs specific line settings (baud rate, parity, stop
* bits), configure the channel after opening with
* p_iow(*pChan, P_FSET, &config);
* where config is an E_CONFIG struct from p_config.h. See the RS232
* section of the PLIB Reference. The module runs at up to 9600 baud.
*/
return p_open(pChan, "TTY:D", (UINT)-1);
}
GLDEF_C VOID bcodeClose(VOID *chan)
{
if (chan != NULL)
p_close(chan);
}
GLDEF_C INT bcodeAssemble(UBYTE *raw, INT n, TEXT *line, INT *pLen, INT max)
{
INT i;
for (i = 0; i < n; i++) {
UBYTE c = raw[i];
if (c == BCODE_TERM) {
line[*pLen] = '\0';
*pLen = 0;
return 1;
}
if (c < ' ') /* skip LF, NULs and other control bytes */
continue;
if (*pLen < max - 1)
line[(*pLen)++] = (TEXT)c;
/* else: overflow - drop until the next terminator */
}
return 0;
}