feat(inventory): Phase 1 - scan and validate UPC barcodes #1

Open
lyrathorpe wants to merge 54 commits from feat/inventory-phase1-scan into main
Showing only changes of commit 8fe13f6ef8 - Show all commits
+43
View File
@@ -0,0 +1,43 @@
/*
* bcode.h - barcode scanner input via the Workabout serial port.
*
* On the Workabout the barcode module decodes the label in hardware and
* delivers the result as an RS232 stream, so a scan is simply read from the
* serial channel using the standard PLIB serial I/O. The scanner here is on
* the top internal slot, which is port D -> device "TTY:D".
*/
#ifndef BCODE_H
#define BCODE_H
#include <plib.h>
/*
* Terminator the scanner appends after each decoded barcode. Most serial
* barcode readers send a carriage return (0x0D). If yours sends LF or a
* different suffix, change this to match its configuration.
*/
#define BCODE_TERM 0x0D
/* Longest decoded barcode we handle (UPC-A is 12; headroom for EAN etc.). */
#define BCODE_MAXLEN 20
/*
* Open the barcode serial channel (TTY:D). Stores the channel handle in
* *pChan. Returns 0 on success or a negative PLIB error code.
*/
GLREF_C INT bcodeOpen(VOID **pChan);
/* Close a channel opened by bcodeOpen. Safe to call with NULL. */
GLREF_C VOID bcodeClose(VOID *chan);
/*
* Line assembler. Feeds n freshly-read bytes from raw into the caller's line
* buffer (current length *pLen, capacity max). When BCODE_TERM is seen the
* completed, NUL-terminated barcode is left in line, *pLen is reset to 0 and
* 1 is returned. Otherwise returns 0 (more bytes needed). Control bytes below
* space (other than the terminator) are ignored; overflow bytes are dropped
* until the next terminator.
*/
GLREF_C INT bcodeAssemble(UBYTE *raw, INT n, TEXT *line, INT *pLen, INT max);
#endif /* BCODE_H */